The DURRIDGE RAD7
Specification
| FEATURE |
Specification |
| MULTI-MODES |
Continuous Radon Gas Monitor
Long-term/Short-term screener
Sniffer, with small tube "snout", to search for radon and
thoron entry points.
Grab mode protocols for radon in air and water.
|
| MULTI-MEASUREMENTS |
Measures radon in air, soil, and water (with RAD H2O
and RAD AQUA accessories). |
| NOMINAL SENSITIVITY |
Monitor: 0.5 counts/min/pCi/l
Sniffer: 0.25 counts/min/pCi/l |
| RANGE |
0.1 ----> 10,000 pCi/l (4 ---> 400,000 Bq/m3) |
| MEMORY |
1,000 radon concentrations, and associated data. Can be read out on LCD, downloaded to PC and/or printed out on HP IR printer. Summary of run shows high, low, average and standard deviation of readings. |
| PRINCIPLE OF OPERATION |
Electrostatic collection of alpha-emitters with spectral analysis. |
| BUILT-IN AIR PUMP |
Nominal 1 liter/minute flow rate. Inlet air filter
Inlet and outlet air connectors. |
| SPECTRUM PRINTOUT |
High-precision alpha-energy spectrum identifies isotopes
in radon and thoron decay chains. Shows proper operation
of RAAD7 and enables superior RAD7 functionality. |
| FAST LOW-LEVEL READINGS |
In Continuous Monitor mode, RAD7 measures the EPA
action level of 4 pCi/l in just 1 hour (60 minutes), with
standard deviation of 10%. Since the RAD7 has virtually
no background, it has a much lower detection threshold than
other electronic detectors, easily measuring down to below
0.1 pCi/l |
| RECOVERY IN MINUTES |
Recovers from high radon exposure with a 3.05 minute half-life: to less than 10% of peak value in 12 minutes; to less than 1% of peak value in less than 30 minutes. Drops from 20,000 to 1 pCi/l in one hour. |
| TAMPER RESISTANT |
A "Test Lock" command is programmed into the machine to secure your RAD7 against all kinds of intentional or unintentional tampering. |
| AUTO MODE |
This setting starts a test run in Sniff mode, then switches to Normal mode after the first 3 hours. No more waiting for equilibrium. Gives quick response, followed by statistical precision. |
| COMPUTER LCD DISPLAY |
2 line X 16 character, alpha-numeric, easy-to-read display. |
| AUDIBLE RADON COUNT |
Indicates presence and intensity of radon and thoron. May be turned on or off. |
| POWER |
AC or battery powered - 5 AH 6V batteries. Automatic charge
when plugged in and switched on. Continuous battery operation:
24 hours in Sniffer mode; 72 hours in Monitor mode. |
| PRINTER |
Chamjin NewHandy 700 Wireless Infrared Printer |
| RS-232 PORT |
Computer or modem hookup. |
| OPERATING RANGE |
Temperature: 30° - 105° F.(0° - 40° C.)
Humidity: 0 - 100%, non-condensing. |
| WEIGHT/SIZE |
11 pounds (5 kg) complete - 9.5" X 7.5" X 10.5" |
| CASE MATERIAL |
High density polyethylene. |
| |
Description |
| |
| RAD7 PROFESSIONAL: "A remarkable machine!" |
| |
| The RAD7 is, indeed, a remarkable machine - a truly versatile radon
detector of mature and yet still state-of-the-art design. Its
specifications match or exceed those of the most expensive models in the
world. At the same time, it incorporates a number of exclusive
features that are found in no other radon detector, regardless of
price. Incredibly, the RAD7 is affordable. |
| |
| The RAD7 is a sophisticated measuring instrument
that is able to handle complex measurements. It is used in
laboratories and
research work around the globe, by radon testers, mitigators and home inspectors,
in mines and deserts, on the ocean and up volcanoes, at extremes
of temperature. |
| |
| The RAD7 is also the simplest computer-driven electronic
detector to use, with pre-programmed set-ups for common tasks. It's
built to withstand everyday use in the field. A rugged, handsome case
encloses the detector, which is self-contained and
self-sufficient. The RAD7 comes complete, with a built-in air
pump, rechargeable batteries, and a Hewlett-Packard alpha-numeric
graphics printer with infra-red link. The printer can be left in your
office or your car, when desired, and the detector will collect data
and store it for later printing or downloading to a PC. |
| |
| The RAD7 is a Sniffer that uses the
3-minute alpha decay of a radon daughter, without interference from other
radiations, and the instantaneous alpha decay of a thoron daughter. Sniffs out entry points and radon gushers. Recovers in
minutes from high radon exposures. |
| |
| The RAD7 is a Continuous Monitor that measures the EPA
action level of 4 pCi/l, with 10% standard deviation, in one hour. |
| |
| At the end of each run, the detector prints out a complete
report. Check it out. You will see the possibilities of this
machine. Then call us for more information about the extraordinary
RAD7. |
|
RAD7 Electronic Radon Monitor/Sniffer
Operation
|
|
| |
| The RAD7 is so easy to use. It's ready to operate from the moment you turn it on. The first thing you will see is the Setup Review, Showing the current settings. This allows you to check that your machine is set up the way you want it for your intended use. |
| |
| Now you and your RAD7 are ready to go to work. The machine is preset for a 1- or 2-day test... or you can preset for your particular job that day. When you arrive on site, just push the buttons and the test runs automatically. |
| |
| A RAD7 exclusive feature is "Auto" mode. This starts a test in Sniff mode for quick response, a base-line reading. After 3 hours it automatically switches to "Normal" mode for the remainder of the test, assuring statistical precision. |
| |
| You can leave your RAD7 for a 24-hour, 48-hour or any-hour test, knowing that the measurements will be correct, thanks to a RAD7 "exclusive feature" - a "Test Lock" command
that locks the machine until you return. The display shows "DURRIDGE RAD7", the test continues, and no amount of tampering - intentional or unintentinal can influence it. |
| |